Gas interlock system regulations require all commercial kitchens using gas appliances to install and maintain a compliant interlock system, with annual CP42 certification from a Gas Safe registered engineer. AFR Air Conditioning provides professional installation, maintenance, and compliance support to keep your kitchen safe and legally sound.
If you run a restaurant, café, takeaway, or any commercial catering business, gas safety is not optional. Gas interlock system regulations exist to protect your staff, your customers, and your business, and failing to meet them can have serious consequences.
Yet despite the legal obligations being clear, many commercial kitchen owners are still unsure what a gas interlock system actually is, how it works, and what the law requires of them. This guide covers everything you need to know.
A gas interlock system, sometimes called a gas safety interlock system, is a safety device fitted in commercial kitchens that links your gas supply to the performance of your ventilation or extraction system.
In simple terms: if your extraction fan is not running correctly, the interlock system automatically cuts off the gas supply to your appliances. Once adequate airflow is restored, the gas supply resumes.
This failsafe prevents the build-up of dangerous gases such as carbon monoxide and nitrogen dioxide in your kitchen environment. It also reduces the risk of explosion caused by unburned gas accumulating where ventilation has failed.
The system continuously monitors your extraction fan or fans. There are two main methods used to do this:
Differential air pressure switch: This detects the level of static air pressure within the duct. If the airflow drops below the required threshold, the switch triggers and cuts the gas supply.
Electrical current sensor: Rather than measuring air pressure, this monitors the electrical current running to the fan. If the fan stops drawing power as expected, the system shuts off the gas.
Both methods achieve the same result: gas cannot flow to your cooking equipment unless your ventilation system is operating as it should. When the fan is off or underperforming, the gas stays off, too.


Yes. A gas interlock system is a legal requirement for any business operating a commercial kitchen with gas-powered appliances.
This is set out under two key frameworks:
British Standard BS6173 governs the installation and maintenance of gas-fired catering appliances and specifies that a gas safety interlock system must be in place.
The Gas Safety (Installation and Use) Regulations 1998 place a duty on all commercial premises to ensure that gas appliances, pipework, and safety devices are maintained in a safe condition and that all related work is carried out by a Gas Safe registered engineer.
There is no grey area here. If your commercial kitchen uses gas and lacks a compliant interlock system, you are operating outside the law.
Beyond the interlock system itself, gas interlock system regulations sit within a wider set of legal obligations that all commercial kitchen operators must meet. These include:
Annual gas safety inspections: All gas appliances must be inspected by a Gas Safe registered engineer at least once a year. This applies regardless of how frequently the equipment is used.
CP42 Gas Safety Certificate: This is the official safety certificate issued by a Gas Safe registered engineer to confirm that all gas appliances, pipework, and extraction and interlock systems in your commercial kitchen have been inspected and are compliant. It must be renewed annually. Without a current CP42, your business may struggle to satisfy insurance requirements, landlord obligations, or local authority inspections.
Qualified engineers only: It is illegal for anyone who is not Gas Safe registered to carry out any installation, maintenance, or repair work on a gas interlock system or any other gas appliance in a commercial setting. This extends to any subcontractors you bring in.
Employee awareness: All staff operating gas appliances must be trained and confident in identifying potential faults or safety concerns. Understanding what to do if the gas supply is cut off by the interlock system is part of responsible kitchen management.
Any business with a commercial kitchen using gas appliances is required to have a gas interlock system installed. This includes:
If your premises use gas for cooking and food preparation, the regulations apply to you.
Ignoring gas interlock system regulations is not a risk worth taking. The consequences of non-compliance range from financial penalties to criminal prosecution, and in the worst case, they can cost lives.
Businesses found to be operating without a compliant gas interlock system may face:
The cost of installation is modest compared to any of the above outcomes. Compliance protects your team, your customers, and everything you have built.
Installation is only the beginning. Gas interlock systems require ongoing maintenance to remain effective and legally compliant with BS6173 standards.
At a minimum, your system should be inspected and tested by a qualified engineer once a year as part of your CP42 gas safety inspection. This check should confirm that:
Any faults identified during maintenance should be rectified promptly. A system that is installed but not maintained correctly offers no protection and will not satisfy compliance requirements.
Some commercial kitchens also require a gas proving system alongside the interlock system. A gas proving system checks for gas leaks within the pipework before allowing gas to flow to appliances, typically at the start of each trading day.
It does this by pressurising the pipework and monitoring for any drop in pressure that would indicate a leak. If a drop is detected, the gas supply remains locked off until the issue is resolved.
Gas proving systems are particularly relevant in kitchens where appliances are left connected to the gas supply overnight or where there is a higher risk profile. A Gas Safe-registered engineer can advise whether one is required for your specific setup.
Not all gas interlock systems are equal. When specifying or replacing a system, the right choice depends on the size and layout of your kitchen, the number of appliances in use, and the design of your extraction system.
Key considerations include:
Compatibility with your extraction setup: The interlock system must be correctly calibrated to the airflow rates required by your specific canopy and extraction configuration, in line with DW/172 (the Specification for Kitchen Ventilation Systems).
Number of fan circuits: Larger kitchens with multiple extraction zones may require more complex interlock configurations.
Sensor type: Differential pressure switches and current sensors each have specific advantages depending on the installation environment. Your engineer will specify the most appropriate option.
Certification and quality: Only systems installed by Gas Safe-registered engineers using appropriate, compliant equipment will satisfy regulatory requirements.
At AFR Air Conditioning, we work with commercial kitchen operators across [region] to install, maintain, and certify gas interlock systems that meet all current UK regulations.
Our Gas Safe-registered engineers carry out full system installations, annual CP42 inspections, and ongoing maintenance programmes tailored to the demands of busy commercial kitchens. Whether you are setting up a new kitchen, replacing an ageing interlock system, or simply unsure whether your current setup is compliant, we can help.
Get in touch with the AFR team today to book a compliance assessment or discuss your requirements.

Only Gas Safe-registered engineers with the appropriate commercial catering qualifications are legally permitted to install, service, or repair gas interlock systems.
At a minimum, once a year as part of your CP42 gas safety inspection. The engineer will test the airflow detection, gas cut-off function, and all system components.
You risk prosecution by the HSE, mandatory kitchen closure, failed gas safety inspections, voided insurance, and significant fines. Non-compliance is treated seriously under UK health and safety law.
The primary legislation is the Gas Safety (Installation and Use) Regulations 1998, supported by British Standard BS6173. Together, these set out the requirement for gas interlock systems, annual safety inspections, and the use of Gas Safe-registered engineers for all related work.
It monitors the performance of your extraction fan using either a differential air pressure switch or an electrical current sensor. If airflow drops below the required level, the gas supply is automatically shut off until ventilation is restored.
Yes. Under British Standard BS6173 and the Gas Safety (Installation and Use) Regulations 1998, any commercial kitchen operating gas appliances must have a compliant gas interlock system installed.
A gas interlock system is a safety device that automatically cuts off the gas supply to commercial kitchen appliances if the extraction ventilation system is not working properly. It prevents the build-up of dangerous gases and reduces the risk of explosion.
Whether you're setting up a new commercial kitchen, due for your annual CP42 inspection, or simply not sure whether your current gas interlock system meets regulations, AFR Air Conditioning is here to help.
We're Gas Safe-registered engineers with hands-on experience across commercial catering environments. From full system installations to routine maintenance and certification, we make compliance straightforward so you can focus on running your business.
Contact our team today for a no-obligation chat about your kitchen's gas safety requirements. We'll assess your current setup, identify any gaps, and give you a clear picture of what needs to be done.